Analyzing Particle Size of Calcium Carbonates Using Laser Diffraction

2022-06-24 23:01:51 By : Ms. Summer Xia

We use cookies to enhance your experience. By continuing to browse this site you agree to our use of cookies. More info.

This article outlines the technique to analyze the particle size of calcium carbonates using laser diffraction.

Calcium carbonates fulfill a wide variety of functions in different industries:

Calcium carbonates are available with varied surface coatings and particle sizes in order to provide this range of functionality. The Mastersizer 3000 laser diffraction system is capable of measuring particle size from nanometers to millimeters, and also allows measurements over the range to be achieved within a few minutes.

This range and measurement speed allows the particle size of calcium carbonates to be tracked during the production processes as well as in quality control of end products.

The Mastersizer 3000 laser diffraction system has a variety of accessories that enable the use of dry dispersion or liquid for measurements. The calcium carbonate’s particle size and processing method will establish whether dry dispersion or liquid is preferable.

Huge sample volumes can be measured using dry dispersion, providing reproducible results for coarser particle sizes. Liquid dispersion provides more control over the dispersion state for the finest grades, producing reproducible results.

The Mastersizer 3000 installation can be used to examine a range of samples because of the ability to rapidly change between dry and liquid dispersion units.

Compressed air is used by the Aero S dry powder disperser to disperse the sample, and the dispersion is ensured by selecting the suitable air pressure. In liquid dispersion, calcium carbonates are generally measured in water using the Hydro dispersion units.

A short duration of ultrasound is needed to disperse agglomerates, and additives such as sodium hexametaphosphate or sodium pyrophosphate are used to stabilize the dispersion.

Figure 1 displays the particle size distributions for a calcium carbonate sample that is measured using both dry (at 1bar) and liquid dispersion (after 1 minute of ultrasound). These findings highlight the positive agreement between dry and liquid dispersion which confirms that that the sample is completely dispersed in both states.

Figure 1. Overlay of a calcium carbonate sample measured in liquid (wet) and dry dispersion

Laser diffraction creates volume-based particle size distributions, which allow a wide range of parameters to be specified. For example, the 10th percentile (Dv10) can be employed to detect the fine particles in the distribution, whereas the 90th percentile (Dv90) helps to detect the coarse particles in the distribution.

In addition to this, calcium carbonates are often specified on the percentage material in specific size ranges, for example the percentage above 10 µm or 45 µm at the coarser end of the range and the percentage below 1 µm and 2 µm for the finer grades.

Figure 2 displays the particle size distributions for four grades of calcium carbonate covering a size range from 0.1 µm up to 1000 µm, and Table 1 highlights the parameters for these samples.

Figure 2. Particle size distributions for four grades of calcium carbonate.

Table 1. Particle size parameters for four grades of calcium carbonate.

Laser diffraction is a technique that is commonly used to analyze calcium carbonates due to its flexible dispersion options, wide dynamic range, reproducibility of results, and measurement speed.

This information has been sourced, reviewed and adapted from materials provided by Malvern Panalytical.

For more information on this source, please visit Malvern Panalytical.

Please use one of the following formats to cite this article in your essay, paper or report:

Malvern Panalytical. (2019, September 03). Analyzing Particle Size of Calcium Carbonates Using Laser Diffraction. AZoM. Retrieved on June 24, 2022 from https://www.azom.com/article.aspx?ArticleID=13146.

Malvern Panalytical. "Analyzing Particle Size of Calcium Carbonates Using Laser Diffraction". AZoM. 24 June 2022. <https://www.azom.com/article.aspx?ArticleID=13146>.

Malvern Panalytical. "Analyzing Particle Size of Calcium Carbonates Using Laser Diffraction". AZoM. https://www.azom.com/article.aspx?ArticleID=13146. (accessed June 24, 2022).

Malvern Panalytical. 2019. Analyzing Particle Size of Calcium Carbonates Using Laser Diffraction. AZoM, viewed 24 June 2022, https://www.azom.com/article.aspx?ArticleID=13146.

dear sir there are an ablitiy to can measurement of particle size for coated calcium carbonate ( fatty acid coating ) thanks

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of AZoM.com.

Do you have a question you'd like to ask regarding this article?

AZoM spoke with James Baker from [email protected] about the growth of graphene as an advanced material and its potential to shape the sustainable future of multiple sectors.

AZoM speaks with Alan Banks from Ford Motor Company about the significance of using lightweight materials in vehicles to improve fuel efficiency and the sustainability of the industry.

AZoM speaks with Joseph Toombs, a Ph.D. student at the University of California, Berkeley, about his research that has developed a new 3D printing process for the manufacture of small glass objects.

This product profile outlines the MAX-iR FTIR Gas Analyzer from Thermo Fisher Scientific.

Learn more about the JAM-5200EBM E-Beam Metal Additive Manufacturing System for 3D Printing.

This product profile outlines the features and benefits of the Contour X - 500 3D Optical Profilometer.

AZoM.com - An AZoNetwork Site

Owned and operated by AZoNetwork, © 2000-2022